Attention: your browser could be obsolete
Please update your browser for a better experience on this website
The Bonfiglioli Active Series contains flexible frequency inverters that are both versatile and easy to use. This product features high performance control and unbeatable advantages in scalability and compact size.

Specifications

  • Types & powers (ACT401)

    Type | Power kW*
    ACT401 - 05 | 0.55
    ACT401 - 07 | 0.75
    ACT401 - 09 | 1.10
    ACT401 - 11 | 1.50
    ACT401 - 12 | 1.85
    ACT401 - 13 | 2.20
    ACT401 - 15 | 3.00
    ACT401 - 18 | 4.00
    ACT401 - 19 | 5.50
    ACT401 - 21 | 7.50
    ACT401 - 22 | 9.20
    ACT401 - 23 | 11.00
    ACT401 - 25 | 15.00
    ACT401 - 27 | 18.50
    ACT401 - 29 | 22.00
    ACT401 - 31 | 30.00
    ACT401 - 33 | 37.00
    ACT401 - 35 | 45.00
    ACT401 - 37 | 55.00
    ACT401 - 39 | 65.00
    ACT401 - 43 | 75.00
    ACT401 - 45 | 90.00
    ACT401 - 47 | 110.00
    ACT401 - 49 | 132.00
  • Types & powers (ACT201)

    Type | Power kW*
    ACT201 - 05 | 0.55
    ACT201 - 07 | 0.75
    ACT201 - 09 | 1.10
    ACT201 - 11 | 1.50
    ACT201 - 13 | 2.20
    ACT201 - 15 | 3.00
    ACT201 - 18 | 4.00
    ACT201 - 19 | 5.50
    ACT201 - 21 | 7.50
    ACT201 - 22 | 9.20
  • Main options

    DC 24 V power supply output
    • EM-IO-02: Expansion for 3 digital inputs, 1 relay output, 1 analog input, 1 analog output, motor-PTC input, system bus connection, DC 24 V power supply output
    • EM-IO-03: Expansion for 2 digital inputs, 1 relay output, 1 analog input, 2 analog outputs, motor-PTC input, system bus connection, DC 24 V power supply output
    • EM-IO-04: Expansion for 2 digital inputs, 1 digital port (input or output), motor-PTC input, system bus connection, DC 24 V power supply output

    Optional encoder & feedback evaluation:
    • EM-ENC-01: TTL/HTL encoder input (2 channels), encoder emulation output (2 channels), 1 analog input, system bus connection, DC 5 V power supply output
    • EM-ENC-02: TTL/HTL encoder input (2 channels), 1 digital port (input or output), 1 analog input, 1 analog output, system bus connection, DC 5 V power supply output
    • EM-ENC-03: TTL/HTL encoder input (2 channels), system bus connection
    • EM-ENC-04: TTL/HTL encoder input (3 channels), 1 relay output, 1 analog input, 1 analog output, 24 V power supply output, DC 5 V power supply output
    • EM-ENC-05: TTL/HTL encoder input (3 channels), 1 analog input, 1 analog output, system bus connection, 24 V power supply output, DC 5 V power supply output
    • EM-RES-01: Resolver input, encoder emulation output (2 channels), 1 analog input, system bus connection
    • EM-RES-02: Resolver input, encoder emulation output (3 channels), 1 analog input

    Optional PC software
    VPlus for Windows with setup, terminal monitor, actual value window, and scope function

    Accessories:
    Brake resistors Type BR: The brake resistors offer an inexpensive solution to dissipate generator power that occurs at deceleration. A thermal sensor for the brake resistor protects the resistor from overheating.
    Power choke type LCVS & LCVT: Power choke types LCVS (for single-phase power installation) and LCVT (for three-phase power installation) increase the overvoltage protection of the inverter and increase the system's EMC.
    Power filters type FTV: Depending on the application boundaries, certain EMC levels must be achieved. The power filters are a component to improve EMC behavior in a machine installation.
  • Degree of protection

    IP20 (EN 60529)
  • Rated speed

    0...599 Hz
  • Certifications

    UL508c
  • Conformity

    CE
    EN61800
  • Power Supply

    ACT401:
    0.55 - 132 kW / three-phase 360 - 480V / 50 - 60 Hz (± 10%)

    ACT201:
    0.55 - 9.2 kW / single or three-phase 200 - 240V / 50 - 60 Hz (± 10%)
  • Software features

    Main software features
    • Programmable reference value channel
    • Programmable start and stop characteristics
    • Motor potentiometer
    • Programmable S curve
    • 4 data sets
    • Auto startup and commissioning
    • Auto reset after failure
    • Auto start after power failure
    • PL controller
    • Programmable logic and timer functions
    • Volume flow control
    • Bumpless torque/speed changeover,
    • Master/slave function with electronic gear,
    • Simple positioning function,
    • Mechanical brake control free of friction
    • Index control
    • Intelligent current limits
    • Power failure control
    • Comprehensive monitoring and protection capabilities
    • High speed control
    • Functions for lift, crane and winch applications
    • 3 different brake management functions.
  • Hardware features

    Integrated dynamic braking module
    DC link connection
    Standard HTL encoder interface
    Motor temperature monitoring
    Plug-in power terminals (up to 3kW)
    Plug-in and programmable control terminals
    6 digital input, 1 multifunction input
    1 digital output, 1 multifunction output
    1 relay output (changeover contact)
  • Power range

    Power range:
    ACT401: 0.55 - 132 kW / three-phase 360 - 480V / 50 - 60 Hz (± 10%)
    Power range (ACT201)
    0.55 - 9.2 kW / single or three-phase 200 - 240V / 50 - 60 Hz (± 10%)
    Overload capacity:
    100 % Continuous output
    up to 150 % for 60 s
    up to 200 % for 1 s
    Switching frequencies 2,4,8,12,16 kHz (availability depending on power size)
    EMC filter integrated up to 9.2 kW (EN61800-3)
    Power range (ACT201)
    0.55 - 9.2 kW / single or three-phase 200 - 240V / 50 - 60 Hz (± 10%)
  • Mounting options

    Cabinet mounting for all sizes
    Optional feed-through mounting
    Optional DIN rail mounting frame size 1
    Optional ColdPlate mounting
  • Motors

    Motor compatibility
    Two types of motors:
    Asynchronous AC motors
    Permanent magnet synchronous (brushless) motors

Key features

Field-oriented control with or without encoder

Applications

Scroll

Related Products

Download Documents

Product Range Catalogue- Mechatronic Drives & Solutions

Product Range Catalogue- Mechatronic Drives & Solutions
en

Download technical documentation

Register now to download the following documents
  • APPLICATION MANUAL CRANE DRIVES-PREMIUM-INVERTERS ACTIVE
  • APPLICATION MANUAL ELECTRONIC GEARS - PREMIUM INVERTERS ACTIVE
  • Braking resistors manual - Inverters & Servo drives
  • Brief manual- Active Series Inverters
  • Communication Modules Manual Inverters-&-Servo Drives-Cm-232-485-Modbus_E
  • Communication Modules Manual Inverters & Servo Drives
  • Communication Modules Manual Inverters & Servo-Drives
  • Communication Modules Manual Inverters & Servo Drives Em-Sys
  • Communication Modules Manual Premium Inverters Cm-Can
  • Expansion Modules Manual-Inverters & Servo-Drives - Em-Enc-01
  • Expansion Modules Manual-Inverters & Servo Drives Em-Enc-02
  • Expansion Modules Manual-Inverters & Servo Drives Em-Enc
  • Expansion Modules Manual- Inverters & Servo Drives Em-Enc-04
  • Expansion Modules Manual- Inverters & Servo Drives Em-Enc
  • Expansion Modules Manual-Inverters & Servo Drives Em-Io-01
  • Expansion Modules Manual Inverters & Servo Drives-Em-Io-02
  • Expansion Modules Manual-Inverters & Servo Drives-Em-Io-03
  • Expansion Modules Manual-Inverters & Servo Drives-EM-IO-04
  • Expansion Modules Manual-Inverters & Servo Drives-EM-RES-01
  • Expansion Modules Manual-Inverters & Servo Drives- EM-RES-02
  • Installation Manual-Inverters & Servo Drives Cold-Plate
  • Installation Manual-Inverters & Servo Drives- Feed Through Mounting
  • Installation Manual- KP-CMK
  • Operating Instructions Module- Premium Inverters-Active
  • Product Catalogue –Premium Inverters- Active
  • Quick Start Guide- Premium Inverters- Active

After having read the privacy disclosure:
By marking the relevant box below, I hereby authorise the company to process my contact data (information on my name, place and date of birth, tax code, address, telephone number, mobile telephone number, e-mail address) for marketing and advertising communication purposes, on promotional sales initiatives, trade fairs and events, receipt of newsletters, carried out using automated contact means (e-mail) and traditional contact means (for example, telephone call with an operator) or for market research and statistical surveys.

I may revoke my declaration of consent at any time to the company for future marketing communications by writing to corporatemkt@bonfiglioli.com

Contact Locator

Bonfiglioli Headquarters
Via Giovanni XXIII, 7/A
40012 Lippo di Calderara di Reno - Bologna (IT)

Contact us Find your contact
Contact us UP
Attention:
browser.javascript.content